Diabetes
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sonnenberg, G. E.
Right arrow Articles by Berger, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sonnenberg, G. E.
Right arrow Articles by Berger, M.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes, Vol 31, Issue 7 600-602, Copyright © 1982 by American Diabetes Association


ARTICLES

Human and porcine regular insulins are equally effective in subcutaneous replacement therapy. Results of a double-blind crossover study in type I diabetic patients with continuous subcutaneous insulin infusion

GE Sonnenberg, E Chantelau, S Sundermann, C Hauff and M Berger

Semisynthetic human Actrapid insulin (HAI, Novo, Copenhagen) was tested against porcine Actrapid insulin (PAI, Novo, Copenhagen) in 12 type I diabetic patients treated with continuous subcutaneous insulin infusion (CSII). In a double-blind crossover trial each patient received both types of insulin over a 3-wk period, respectively. No significant differences between HAI and PAI were observed in the following parameters: mean blood glucose levels (MBG) of 3-6 measurements per day (129 +/- 5 versus 125 +/- 4 mg/dl, means +/- SEM), mean maximal excursions of blood glucose during the day (107 +/- 6.6 versus 107 +/- 6.9 mg/dl), total daily insulin requirements (sum of basal and premeal insulin doses, 45.7 +/- 1.4 versus 42.7 +/- 1.4 U/day), and a mean of weekly determined hemoglobin A1c values (7.77 +/- 0.13 versus 7.83 +/- 0.14% of total hemoglobin); the frequency of mild hypoglycemic episodes was similar with the two insulins. Thus, under the controlled conditions of CSII, semisynthetic human and porcine regular insulin preparations are of identical efficacy in type I diabetic patients at near normoglycemia.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1982 by the American Diabetes Association.