Diabetes
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bright, G. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bright, G. M.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes, Vol 36, Issue 10 1183-1186, Copyright © 1987 by American Diabetes Association


ARTICLES

Quantitative assay for human cytoplasmic islet cell antibodies

GM Bright
Department of Pediatrics, Medical University of South Carolina, Charleston 29425.

An assay for human islet cell antibodies (ICAs) in serum yielding numerical values and amenable to statistical evaluation has been developed utilizing fluorescence spectrophotomicroscopy (FSPM). The results of the blinded trials by FSPM were compared with those by standard indirect immunofluorescence (IFL). No false-positive or false-negative readings were obtained in 258 observations when the results by FSPM were compared with those by IFL. The intra- and interassay variabilities encountered were not enough to misclassify a specimen. The presence of anti-thyroid, anti-adrenal, or anti-nuclear antibodies did not produce false-positive readings. Twenty-eight additional specimens from diabetic children were also analyzed via three blood group type O pancreases. There was complete agreement concerning the presence or absence of ICA between IFL and FSPM analyses. Analysis of the three pancreases yielded different numbers of results positive for ICA (14/28 vs. 22/28 vs. 15/28, P = .008) in both assays. Thus, selection of pancreatic substrate may influence the outcome of assays for ICA. A matrix of fluorescent microspheres has been devised that allows calibration of the FSPM system. Now, reproducible and comparable readings for ICA values can be obtained from the various reporting laboratories. Should an international reference serum for ICA become available, the remaining problem in the ICA assay, that of substrate (pancreas) variability, should be resolved.