Diabetes
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsukuda, K.
Right arrow Articles by Oka, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsukuda, K.
Right arrow Articles by Oka, Y.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes, Vol 40, Issue 3 315-318, Copyright © 1991 by American Diabetes Association


ARTICLES

Peptide-based radioimmunoassay specific for GLUT1 glucose transporter

K Tsukuda, T Asano, JL Lin, H Katagiri, H Ishihara, F Takaku and Y Oka
Third Department of Internal Medicine, Faculty of Medicine, University of Tokyo, Japan.

A radioimmunoassay for the GLUT1 glucose transporter was developed with a synthesized peptide based on the sequence of the cDNA for GLUT1. A peptide corresponding to the COOH-terminal domain of the GLUT1 glucose transporter (Thr-Pro-Glu-Glu-Leu-Phe-His-Pro-Leu-Gly-Ala-Asp-Ser-Gln-Val) was synthesized and conjugated to keyhole limpet hemocyanin through the NH2-terminal of the peptide. An antibody was raised against this complex and affinity purified with the immobilized peptide. A second peptide, with tyrosine residue added to the NH2-terminal of the above peptide, was synthesized and used as a standard and iodinated for preparation of the radioactive ligand. The assay is highly reproducible, sensitive, and specific for the COOH-terminal domain of the GLUT1 glucose transporter. It has no cross-reactivity with the other glucose-transporter isoforms GLUT2 and GLUT4. Furthermore, the results obtained with this radioimmunoassay on the number of glucose transporters in human erythrocytes were in good agreement with previous studies based on cytochalasin B binding, suggesting that this radioimmunoassay is able to quantify the number of glucose transporters. The assay is completed within 4 h and can be used for simultaneous measurement of GLUT1 in many samples. In addition, it can be applied to the measurement of GLUT1 in several types of tissue.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1991 by the American Diabetes Association.