Diabetes
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ritzel, R.
Right arrow Articles by Nauck, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ritzel, R.
Right arrow Articles by Nauck, M. A.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Diabetes 50:776-784, 2001
© 2001 by the American Diabetes Association, Inc.

Glucagon-Like Peptide 1 Increases Secretory Burst Mass of Pulsatile Insulin Secretion in Patients With Type 2 Diabetes and Impaired Glucose Tolerance

Robert Ritzel1, Miriam Schulte1, Niels Pørksen2, Markus S. Nauck3, Jens J. Holst4, Claus Juhl2, Winfried März3, Ole Schmitz2, Wolff H. Schmiegel1, and Michael A. Nauck1

1 Department of Internal Medicine, Ruhr-University, Knappschafts-KH, Bochum, Germany
2 Department of Endocrinology and Metabolism, University of Aarhus, Aarhus, Denmark
3 Department of Clinical Chemistry, University of Freiburg, Freiburg, Germany
4 Department of Medical Physiology, Panum Institute, University of Copenhagen, Copenhagen, Denmark

The insulinotropic gut hormone glucagon-like peptide (GLP)-1 increases secretory burst mass and the amplitude of pulsatile insulin secretion in healthy volunteers without affecting burst frequency. Effects of GLP-1 on secretory mechanisms in type 2 diabetic patients and subjects with impaired glucose tolerance (IGT) known to have impaired pulsatile release of insulin have not yet been studied. Eight type 2 diabetic patients (64 ± 9 years, BMI 28.9 ± 7.2 kg/m2, HbA1c 7.7 ± 1.3%) and eight subjects with IGT (63 ± 10 years, BMI 31.7 ± 6.4 kg/m2, HbA1c 5.7 ± 0.4) were studied on separate occasions in the fasting state during the continued administration of exogenous GLP-1 (1.2 pmol · kg-1 · min-1, started at 10:00 P.M. the evening before) or placebo. For comparison, eight healthy volunteers (62 ± 7 years, BMI 27.7 ± 4.8 kg/m2, HbA1c 5.4 ± 0.5) were studied only with placebo. Blood was sampled continuously over 60 min (roller-pump) in 1-min fractions for the measurement of plasma glucose and insulin. Pulsatile insulin secretion was characterized by deconvolution, autocorrelation, and spectral analysis and by estimating the degree of randomness (approximate entropy). In type 2 diabetic patients, exogenous GLP-1 at ~90 pmol/l improved plasma glucose concentrations (6.4 ± 2.1 mmol/l vs. placebo 9.8 ± 4.1 mmol/l, P = 0.0005) and significantly increased mean insulin burst mass (by 68%, P = 0.007) and amplitude (by 59%, P = 0.006; deconvolution analysis). In IGT subjects, burst mass was increased by 45% (P = 0.019) and amplitude by 38% (P = 0.02). By deconvolution analysis, insulin secretory burst frequency was not affected by GLP-1 in either type 2 diabetic patients (P = 0.15) or IGT subjects (P = 0.76). However, by both autocorrelation and spectral analysis, GLP-1 prolonged the period (lag time) between subsequent maxima of insulin concentrations significantly from ~9 to ~13 min in both type 2 diabetic patients and IGT subjects. Under placebo conditions, parameters of pulsatile insulin secretion were similar in normal subjects, type 2 diabetic patients, and IGT subjects based on all methodological approaches (P > 0.05). In conclusion, intravenous GLP-1 reduces plasma glucose in type 2 diabetic patients and improves the oscillatory secretion pattern by amplifying insulin secretory burst mass, whereas the oscillatory period determined by autocorrelation and spectral analysis is significantly prolonged. This was not the case for the interpulse interval determined by deconvolution. Together, these results suggest a normalization of the pulsatile pattern of insulin secretion by GLP-1, which supports the future therapeutic use of GLP-1–derived agents.


Abbreviations: ELISA, enzyme-linked immunosorbent assay; GIP, gastric inhibitory polypeptide; GLP, glucagon-like peptide; IGT, impaired glucose tolerance


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Endocr. Rev.Home page
B. L. Wajchenberg
{beta}-Cell Failure in Diabetes and Preservation by Clinical Treatment
Endocr. Rev., April 1, 2007; 28(2): 187 - 218.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
R. A. Ritzel, J. D. Veldhuis, and P. C. Butler
The mass, but not the frequency, of insulin secretory bursts in isolated human islets is entrained by oscillatory glucose exposure
Am J Physiol Endocrinol Metab, April 1, 2006; 290(4): E750 - E756.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
G. S. Meneilly, J. D. Veldhuis, and D. Elahi
Deconvolution Analysis of Rapid Insulin Pulses before and after Six Weeks of Continuous Subcutaneous Administration of Glucagon-Like Peptide-1 in Elderly Patients with Type 2 Diabetes
J. Clin. Endocrinol. Metab., November 1, 2005; 90(11): 6251 - 6256.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
F. Fehse, M. Trautmann, J. J. Holst, A. E. Halseth, N. Nanayakkara, L. L. Nielsen, M. S. Fineman, D. D. Kim, and M. A. Nauck
Exenatide Augments First- and Second-Phase Insulin Secretion in Response to Intravenous Glucose in Subjects with Type 2 Diabetes
J. Clin. Endocrinol. Metab., November 1, 2005; 90(11): 5991 - 5997.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
M. A. Nauck, B. Baller, and J. J. Meier
Gastric Inhibitory Polypeptide and Glucagon-Like Peptide-1 in the Pathogenesis of Type 2 Diabetes
Diabetes, December 1, 2004; 53(suppl_3): S190 - S196.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
R. A. Ritzel, J. B. Hansen, J. D. Veldhuis, and P. C. Butler
Induction of {beta}-Cell Rest by a Kir6.2/SUR1-Selective KATP-Channel Opener Preserves {beta}-Cell Insulin Stores and Insulin Secretion in Human Islets Cultured at High (11 mM) Glucose
J. Clin. Endocrinol. Metab., February 1, 2004; 89(2): 795 - 805.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
D. J. Drucker
Enhancing Incretin Action for the Treatment of Type 2 Diabetes
Diabetes Care, October 1, 2003; 26(10): 2929 - 2940.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
R. A. Ritzel, J. D. Veldhuis, and P. C. Butler
Glucose Stimulates Pulsatile Insulin Secretion from Human Pancreatic Islets by Increasing Secretory Burst Mass: Dose-Response Relationships
J. Clin. Endocrinol. Metab., February 1, 2003; 88(2): 742 - 747.
[Abstract] [Full Text] [PDF]


Home page
EndocrinologyHome page
O. G. Chepurny, M. A. Hussain, and G. G. Holz
Exendin-4 as a Stimulator of Rat Insulin I Gene Promoter Activity via bZIP/CRE Interactions Sensitive to Serine/Threonine Protein Kinase Inhibitor Ro 31-8220
Endocrinology, June 1, 2002; 143(6): 2303 - 2313.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
C. B. Juhl, M. Hollingdal, J. Sturis, G. Jakobsen, H. Agerso, J. Veldhuis, N. Porksen, and O. Schmitz
Bedtime Administration of NN2211, a Long-Acting GLP-1 Derivative, Substantially Reduces Fasting and Postprandial Glycemia in Type 2 Diabetes
Diabetes, February 1, 2002; 51(2): 424 - 429.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 2001 by the American Diabetes Association.