Diabetes
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boyne, M. S.
Right arrow Articles by Saudek, C. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boyne, M. S.
Right arrow Articles by Saudek, C. D.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes 52:2790-2794, 2003
© 2003 by the American Diabetes Association, Inc.

Timing of Changes in Interstitial and Venous Blood Glucose Measured With a Continuous Subcutaneous Glucose Sensor

Michael S. Boyne, David M. Silver, Joy Kaplan, and Christopher D. Saudek

From the Division of Endocrinology and Metabolism, Johns Hopkins University School of Medicine and the Applied Physics Laboratory, Johns Hopkins University, Baltimore, Maryland

The objective of this study was to use a subcutaneous continuous glucose sensor to determine time differences in the dynamics of blood glucose and interstitial glucose. A total of 14 patients with type 1 diabetes each had two sensors (Medtronic/MiniMed CGMS) placed subcutaneously in the abdomen, acquiring data every 5 min. Blood glucose was sampled every 5 min for 8 h, and two liquid meals were given. A smoothing algorithm was applied to the blood glucose and interstitial glucose curves. The first derivatives of the glucose traces defined and quantified the timing of rises, peaks, falls, and nadirs. Altogether, 24 datasets were used for the analysis of time differences between interstitial and blood glucose and between sensors in each patient. Time differences between blood and interstitial glucose ranged from 4 to 10 min, with the interstitial glucose lagging behind blood glucose in 81% of cases (95% CIs 72.5 and 89.5%). The mean (±SD) difference between the two sensors in each patient was 6.7 ± 5.1 min, representing random variation in sensor response. In conclusion, there is a time lag of interstitial glucose behind blood glucose, regardless of whether glycemia is rising or falling, but intersensor variability is considerable in this sensor system. Comparisons of interstitial and blood glucose kinetics must take statistical account of variability between sensors.


Address correspondence and reprint requests to Christopher D. Saudek, MD, Johns Hopkins University School of Medicine, Osler 576, 600 North Wolfe St., Baltimore, MD 21287. E-mail: csaudek{at}jhu.edu


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Diabetes CareHome page
B. Buckingham, D. M. Wilson, T. Lecher, R. Hanas, K. Kaiserman, and F. Cameron
Duration of Nocturnal Hypoglycemia Before Seizures
Diabetes Care, November 1, 2008; 31(11): 2110 - 2112.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
H. R Lieberman, C. M Caruso, P. J Niro, G. E Adam, M. D Kellogg, B. C Nindl, and F M. Kramer
A double-blind, placebo-controlled test of 2 d of calorie deprivation: effects on cognition, activity, sleep, and interstitial glucose concentrations
Am. J. Clinical Nutrition, September 1, 2008; 88(3): 667 - 676.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
J. Hermanides, I. M. Wentholt, A. A. Hart, J. B. Hoekstra, and J. H. DeVries
No Apparent Local Effect of Insulin on Microdialysis Continuous Glucose- Monitoring Measurements
Diabetes Care, June 1, 2008; 31(6): 1120 - 1122.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
B. Kovatchev, S. Anderson, L. Heinemann, and W. Clarke
Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors
Diabetes Care, June 1, 2008; 31(6): 1160 - 1164.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
I. M. Wentholt, J. B. Hoekstra, and J. H. DeVries
A Critical Appraisal of the Continuous Glucose-Error Grid Analysis
Diabetes Care, August 1, 2006; 29(8): 1805 - 1811.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
L. Allport, T. Baird, K. Butcher, L. MacGregor, J. Prosser, P. Colman, and S. Davis
Frequency and Temporal Profile of Poststroke Hyperglycemia Using Continuous Glucose Monitoring
Diabetes Care, August 1, 2006; 29(8): 1839 - 1844.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
I. M. Wentholt, M. A. Vollebregt, A. A. Hart, J. B. Hoekstra, and J. H. DeVries
Comparison of a Needle-Type and a Microdialysis Continuous Glucose Monitor in Type 1 Diabetic Patients
Diabetes Care, December 1, 2005; 28(12): 2871 - 2876.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
The Diabetes Research in Children Network (DirecNe
Eight-Point Glucose Testing Versus the Continuous Glucose Monitoring System in Evaluation of Glycemic Control in Type 1 Diabetes
J. Clin. Endocrinol. Metab., June 1, 2005; 90(6): 3387 - 3391.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
J. K. Nielsen, C. B. Djurhuus, C. H. Gravholt, A. C. Carus, J. Granild-Jensen, H. Orskov, and J. S. Christiansen
Continuous Glucose Monitoring in Interstitial Subcutaneous Adipose Tissue and Skeletal Muscle Reflects Excursions in Cerebral Cortex
Diabetes, June 1, 2005; 54(6): 1635 - 1639.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
A. G. Pittas, R. Hariharan, P. C. Stark, C. L. Hajduk, A. S. Greenberg, and S. B. Roberts
Interstitial Glucose Level Is a Significant Predictor of Energy Intake in Free-Living Women with Healthy Body Weight
J. Nutr., May 1, 2005; 135(5): 1070 - 1074.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
B. P. Kovatchev, L. A. Gonder-Frederick, D. J. Cox, and W. L. Clarke
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors: Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data
Diabetes Care, August 1, 2004; 27(8): 1922 - 1928.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum